Our platform & passenger lifts range are suitable for a variety of applications, with experience in all sectors including special expertise in residential and new build apartments, student accommodation, schools, offices, hospitals and existing buildings we are here to work with you for all your passenger lift requirements.
From 6 to 33 person, with ultra-compact lift installations in traditional build and a unique range of solutions for OFFSITE construction such as Timber Frame, Modular and Light Gauge Steel (LGS) using our Ideal Lifts Frame System.
Ideal Lifts offer a comprehensive range of lifts with contemporary finishes to suit your building needs.
IL1 / Platform Lift
| Ideal Model Name / Lift Type | ||||||||
| Accessibility Standards | ||||||||
| BS EN 81-41 & Part M4 (1) – Category 1 | ||||||||
| Evacuation Control | ||||||||
| N/A | ||||||||
| Firefighting | ||||||||
| N/A | ||||||||
| Vandal Resistant | ||||||||
| N/A | ||||||||
| Motor Starts (Per hour) | ||||||||
| 30 | ||||||||
| SPEED (Metres per second) | ||||||||
| 0.15 m/s | ||||||||
| Up to X No. of Floors | ||||||||
| 4 | ||||||||
| Power Options | ||||||||
| Single Phase | ||||||||
| Ideal Model Name / Lift Type | ||||||||
| IL2 / Hybrid Access | ||||||||
| Accessibility Standards | ||||||||
| BS EN 81-41 & Part M4 (1) – Category 1 | ||||||||
| Evacuation Control | ||||||||
| N/A | ||||||||
| Firefighting | ||||||||
| N/A | ||||||||
| Vandal Resistant | ||||||||
| N/A | ||||||||
| Motor Starts (Per hour) | ||||||||
| 30 | ||||||||
| SPEED (Metres per second) | ||||||||
| 0.15 m/s | ||||||||
| Up to X No. of Floors | ||||||||
| 4 | ||||||||
| Power Options | ||||||||
| Single Phase | ||||||||
| Ideal Model Name / Lift Type | ||||||||
| IL3 / Passenger | ||||||||
| Accessibility Standards | ||||||||
| BS EN 81-70 & Part M4(1) and M4 (2) | ||||||||
| Evacuation Control | ||||||||
| BS9999 | ||||||||
| Firefighting | ||||||||
| N/A | ||||||||
| Vandal Resistant | ||||||||
| BS EN 81-71 Category 1 | ||||||||
| Motor Starts (Per hour) | ||||||||
| 180 | ||||||||
| SPEED (Metres per second) | ||||||||
| 0.5 m/s | ||||||||
| Up to X No. of Floors | ||||||||
| 5 | ||||||||
| Power Options | ||||||||
| Single and Three Phase | ||||||||
| Ideal Model Name / Lift Type | ||||||||
| IL4 / Passenger | ||||||||
| Accessibility Standards | ||||||||
| BS EN 81-70 & Part M4(1) and M4 (2) | ||||||||
| Evacuation Control | ||||||||
| BS9999 | ||||||||
| Firefighting | ||||||||
| BS EN 81-72 | ||||||||
| Vandal Resistant | ||||||||
| BS EN 81-71 Category 1 & 2 | ||||||||
| Motor Starts (Per hour) | ||||||||
| 180 | ||||||||
| Speed (Metres per second) | ||||||||
| 1 m/s – 1.6 m/s | ||||||||
| Up to X No. of Floors | ||||||||
| 12 | ||||||||
| Power Options | ||||||||
| Three Phase | ||||||||
| N.B. 13 P (1000kg) and above are only available in Three Phase | ||||||||
| Ideal Model Name / Lift Type | Accessibility Standards | Evacuation Control | Firefighting | Vandal Resistant | Motor Starts (Per hour) | Speed (Metres per second) | Up to X No. of Floors | Power Options |
| IL1 / Platform Lift | BS EN 81-41 & Part M4 (1) – Category 1 | N/A | N/A | N/A | 30 | 0.15 m/s | 4 | Single Phase |
| IL2 / Hybrid Access | BS EN 81-41 & Part M4 (1) – Category 1 | N/A | N/A | N/A | 30 | 0.15 m/s | 4 | Single Phase |
| IL3 / Passenger | BS EN 81-70 & Part M4(1) and M4 (2) | BS9999 | N/A | BS EN 81-71 Category 1 | 180 | 0.5 m/s | 5 | Single and Three Phase |
| IL4 / Passenger | BS EN 81-70 & Part M4(1) and M4 (2) | BS9999 | BS EN 81-72 | BS EN 81-71 Category 1 & 2 | 180 | 1 m/s – 1.6 m/s | 12 | Three Phase |
| N.B. 13 P (1000kg) and above are only available in Three Phase | ||||||||
| Ideal Model Name / Lift Type | ||||||||
| IL3 / Passenger | ||||||||
| Accessibility Standards | ||||||||
| BS EN 81-70 & Part M4(1) and M4 (2) | ||||||||
| Evacuation Control | ||||||||
| BS9999 | ||||||||
| Firefighting | ||||||||
| N/A | ||||||||
| Vandal Resistant | ||||||||
| BS EN 81-71 Category 1 | ||||||||
| Motor Starts (Per hour) | ||||||||
| 180 | ||||||||
| SPEED (Metres per second) | ||||||||
| 0.5 m/s | ||||||||
| Up to X No. of Floors | ||||||||
| 5 | ||||||||
| Power Options | ||||||||
| Single and Three Phase | ||||||||
| Ideal Model Name / Lift Type | ||||||||
| IL4 / Passenger | ||||||||
| Accessibility Standards | ||||||||
| BS EN 81-70 & Part M4(1) and M4 (2) | ||||||||
| Evacuation Control | ||||||||
| BS9999 | ||||||||
| Firefighting | ||||||||
| BS EN 81-72 | ||||||||
| Vandal Resistant | ||||||||
| BS EN 81-71 Category 1 & 2 | ||||||||
| Motor Starts (Per hour) | ||||||||
| 180 | ||||||||
| Speed (Metres per second) | ||||||||
| 1 m/s – 1.6 m/s | ||||||||
| Up to X No. of Floors | ||||||||
| 12 | ||||||||
| Power Options | ||||||||
| Three Phase | ||||||||
| N.B. 13 P (1000kg) and above are only available in Three Phase | ||||||||
The IL1 platform access lift offers a self-supporting structure and the market’s smallest footprint with no structural fixings.
Our platform lift range is a cost-effective solution for accessibility requirements. With DDA-compliant options available, the IL1 Platform Lift is the ideal solution for wheelchair lift requirements.
The IL2 hybrid access range, whist travelling at a lower speed, offers much of the functionality of a conventional passenger lift. With a fully enclosed cabin and automatic ‘one touch’ controls. The IL2 is designed to fit in only a 150mm pit and 2750mm headroom. In keeping with BS EN 81-41 the IL2 has a drive system designed for low use.
The IL4 passenger lift range is for larger buildings and busy environments – to carry people higher and faster. Fitted with a premium variable speed motor room-less (MRL) gearless traction drive, and can achieve 2 BREEAM credits. Our IL4 passenger lifts offer safety, reliability and choice in equal measures. Fully compliant BS EN 81-71, Category 1 & 2, Vandal Resistant lifts, and BS9999 Evacuation Control lifts are also available in this model.
Our most popular models are detailed below, please contact us to discuss additional lift models and sizes not listed below.
| Lift Model Data Sheet No. Motor Room Less (MRL) Traction Drive | Capacity Passengers / Kg | Speed (m/s) | Clear Doors Openings | Accessibility – Compliant with BS EN 81-70 Harmonised Standards & Building Regulations (Part M) | Internal Car Width | Internal Car Depth | Internal Shaft Width to Fire Line Finish | Internal Shaft Depth to Fire Line Finish Landing entrances without threshold rebates Single Entrance (Through Car) | Pit Depth Below Finished Floor Level † (BS EN 81-20/50 compliant) | Headroom Above Finished Floor Level Including Lifting Beam |
| IL3E_F_630KG_C | 8 / 630 | 0.5 | 900 2 PSO | Type 2 M4 (2) Cat 2 | 1100 | 1400 | 1740 | 1900 (2040) | 1080 | 3650 |
| IL4_F_630KG_C | 8 / 630 | 1.0 | 900 2 PSO | Type 2 M4 (2) Cat 2 | 1100 | 1400 | 1740 | 1900 (2040) | 1080 | 3650 |
| IL3E_F_630KG | 8 / 630 | 0.5 | 900 2 PSO | Type 2 M4 (2) Cat 2 | 1100 | 1400 | 1830 | 1900 (2040) | 1080 | 3650 |
| IL4_F_630KG | 8 / 630 | 1.0 | 900 2 PSO | Type 2 M4 (2) Cat 2 | 1100 | 1400 | 1830 | 1900 (2040) | 1080 | 3650 |
| IL3E _F_1000KG | 13 / 1000 | 0.5 | 900 2 PSO | Type 3 M4 (2) Cat 2 | 1100 | 2100 | 1850 | 2580 (2740) | 1080 | 3650 |
| IL4_F_1000KG | 13 / 1000 | 1.0 | 900 2 PSO | Type 3 M4 (2) Cat 2 | 1100 | 2100 | 1850 | 2580 (2740) | 1080 | 3650 |
Our most popular models are detailed below, please contact us to discuss additional lift models and sizes not listed below.
| Lift Model Data Sheet No. Motor Room Less (MRL) Traction Drive | ||||||||||
| IL3E_F_630KG_C | Capacity Passengers / Kg 8 / 630 | Speed (m/s) 0.5 | Clear Doors Openings 900 2 PSO | Accessibility – Compliant with BS EN 81-70 Harmonised Standards & Building Regulations (Part M) Type 2 M4 (2) Cat 2 | Internal Car Width 1100 | Internal Car Depth 1400 | Internal Shaft Width to Fire Line Finish 1740 | Internal Shaft Depth to Fire Line Finish Landing entrances without threshold rebates Single Entrance (Through Car) 1900 | Pit Depth Below Finished Floor Level † (BS EN 81-20/50 compliant) 1080 | Headroom Above Finished Floor Level Including Lifting Beam 3650 |
| IL4_F_630KG_C | Capacity Passengers / Kg 8 / 630 | Speed (m/s) 1.0 | Clear Doors Openings 900 2 PSO | Accessibility – Compliant with BS EN 81-70 Harmonised Standards & Building Regulations (Part M) Type 2 M4 (2) Cat 2 | Internal Car Width 1100 | Internal Car Depth 1400 | Internal Shaft Width to Fire Line Finish 1740 | Internal Shaft Depth to Fire Line Finish Landing entrances without threshold rebates Single Entrance (Through Car) 1900 | Pit Depth Below Finished Floor Level † (BS EN 81-20/50 compliant) 1080 | Headroom Above Finished Floor Level Including Lifting Beam 3650 |
| IL3E_F_630KG | Capacity Passengers / Kg 8 / 630 | Speed (m/s) 0.5 | Clear Doors Openings 900 2 PSO | Accessibility – Compliant with BS EN 81-70 Harmonised Standards & Building Regulations (Part M) Type 2 M4 (2) Cat 2 | Internal Car Width 1100 | Internal Car Depth 1400 | Internal Shaft Width to Fire Line Finish 1830 | Internal Shaft Depth to Fire Line Finish Landing entrances without threshold rebates Single Entrance (Through Car) 1900 | Pit Depth Below Finished Floor Level † (BS EN 81-20/50 compliant) 1080 | Headroom Above Finished Floor Level Including Lifting Beam 3650 |
| IL4_F_630KG | Capacity Passengers / Kg 8 / 630 | Speed (m/s) 1.0 | Clear Doors Openings 900 2 PSO | Accessibility – Compliant with BS EN 81-70 Harmonised Standards & Building Regulations (Part M) Type 2 M4 (2) Cat 2 | Internal Car Width 1100 | Internal Car Depth 1400 | Internal Shaft Width to Fire Line Finish 1830 | Internal Shaft Depth to Fire Line Finish Landing entrances without threshold rebates Single Entrance (Through Car) 1900 | Pit Depth Below Finished Floor Level † (BS EN 81-20/50 compliant) 1080 | Headroom Above Finished Floor Level Including Lifting Beam 3650 |
| IL3E _F_1000KG | Capacity Passengers / Kg 13 / 1000 | Speed (m/s) 0.5 | Clear Doors Openings 900 2 PSO | Accessibility – Compliant with BS EN 81-70 Harmonised Standards & Building Regulations (Part M) Type 3 M4 (2) Cat 2 | Internal Car Width 1100 | Internal Car Depth 2100 | Internal Shaft Width to Fire Line Finish 1900 | Internal Shaft Depth to Fire Line Finish Landing entrances without threshold rebates Single Entrance (Through Car) 2650 | Pit Depth Below Finished Floor Level † (BS EN 81-20/50 compliant) 1080 | Headroom Above Finished Floor Level Including Lifting Beam 3650 |
| IL4_F_1000KG | Capacity Passengers / Kg 13 / 1000 | Speed (m/s) 1.0 | Clear Doors Openings 900 2 PSO | Accessibility – Compliant with BS EN 81-70 Harmonised Standards & Building Regulations (Part M) Type 3 M4 (2) Cat 2 | Internal Car Width 1100 | Internal Car Depth 2100 | Internal Shaft Width to Fire Line Finish 1900 | Internal Shaft Depth to Fire Line Finish Landing entrances without threshold rebates Single Entrance (Through Car) 2650 | Pit Depth Below Finished Floor Level † (BS EN 81-20/50 compliant) 1080 | Headroom Above Finished Floor Level Including Lifting Beam 3650 |
As part of our enhanced passenger lift specifications we can include the following equipment, if required:
Yes, please visit Breeam Compliance for further information.
Yes, please visit Hybrid Platform Lifts.
Yes, please visit our Accessibility Guide.
Yes, please visit Evacuation Control Lifts.
Yes, please visit Firefighting Lifts.
Yes, please visit Vandal Resistant Lifts.
We mostly provide 8-Person and 13-Person lifts but can accommodate from 4-P to 33-P, see more information about our lift shaft size requirements here.
Yes, please visit Open Protocol.
One of our team will contact you shortly.