One of the most common questions we hear from building owners, managing agents and facilities managers is: “How long do lifts last?”
The answer is often longer than many people expect. A professionally maintained lift can frequently remain in service for 25 to 50 years, with some installations continuing to operate beyond this through carefully planned modernisation and component replacement.
However, while the lift structure itself may last many decades, many of its critical electrical and mechanical components will require significant investment long before the entire lift reaches the end of its life.
Understanding the lifecycle of a lift is essential for planning maintenance budgets, avoiding unexpected breakdowns and protecting the long-term value of your building.

© Nuttapong Jeenpadipat / Shutterstock
A Lift Doesn’t Have a Single Expiry Date
Unlike many building systems, lifts rarely reach a specific age where they automatically need replacing.
The lift lifespan depends on factors such as:
- Usage levels
- Quality of the original installation
- Environmental conditions
- Maintenance standards
- Availability of spare parts
- Technological obsolescence
A lift serving a small residential block may remain reliable for many years beyond its expected design life, while a heavily used commercial lift could require major upgrades much sooner.
The more important question is often not how old is the lift, but rather:
- Is it reliable?
- Are spare parts still available?
- Are maintenance costs increasing?
- Does it still meet modern expectations and safety standards?
What Does LG1 Mean for Older Lifts?
As lifts age, their condition should be assessed more closely.
Industry guidance, known as LG1 (Guidelines on the Supplementary Tests of In-Service Lifts), provides a framework for additional examinations that may be recommended by a Competent Person during a thorough examination, particularly where lift components have been in service for many years. These tests help identify hidden deterioration, wear and fatigue that may not be visible during routine inspections.
For building owners, LG1 testing can provide valuable information about the condition of ageing equipment and help inform decisions on lift repair, modernisation or replacement. Rather than waiting for failures to occur, it supports a more proactive approach to asset management. [safed.co.uk], [leia.co.uk]
The 15 to 30 Year Investment Window
While the lift car, shaft equipment and landing doors may continue operating for several decades, certain key systems typically require replacement between 15 and 30 years.
Control Systems
The controller is the “brain” of the lift, managing movement, door operation, safety circuits and diagnostics. After 15 to 25 years, some controllers can become increasingly difficult to support due to obsolete electronics and diminishing spare part availability. Rising breakdown frequency, longer repair times and recurring faults are all common indicators that a lift modernisation should be considered.
A controller replacement can often deliver substantial improvements in reliability, fault diagnostics, remote monitoring capability and overall performance without the cost of a complete lift replacement.
Hydraulic Systems
For hydraulic lifts, the hydraulic package represents another major lifecycle investment.
Components may include:
- Power unit incorporating the pump and motor assembly
- Hydraulic valve block
- Hoses
- Ram seals
As systems approach 20 to 30 years wear, efficiency losses and component obsolescence can make refurbishment or replacement the most cost-effective choice.
Modern hydraulic equipment can improve reliability, reduce energy consumption and provide smoother operation for passengers.
The Cost of Waiting Too Long
Many building owners understandably continue repairing a lift while it remains operational. However, there is often a tipping point where reactive maintenance becomes more expensive than planned investment.
Warning signs include:
- Increased breakdowns
- Repeated faults
- Rising maintenance expenditure
- Extended downtime
- Difficulty in sourcing parts
- Growing lift user complaints
Planning modernisation works before these issues become critical usually results in lower overall costs and less disruption for building occupants.
A Sensible Budgeting Strategy
We generally recommend adopting a long-term lifecycle approach:
0-15 Years
Routine lift maintenance and statutory inspections.
15-25 Years
Assess the condition of control systems, parts availability and reliability trends. Consider LG1-related recommendations arising from thorough lift examinations or set intervals.
20-30+ Years
Budget for major modernisation works, including controller upgrades and hydraulic system replacement where applicable. Establishing sinking funds or reserve budgets during this period can help avoid unexpected capital expenditure and spread future lift modernisation costs more effectively.
The Bottom Line
A well-maintained lift can often provide reliable service for 25 to 50 years or more. However, owners should expect significant investment in critical systems during the 15 to 30 year period, particularly control equipment and hydraulic systems.
By monitoring condition, acting on LG1 recommendations where applicable, and budgeting for modernisation in advance, building owners can extend lift lifespan, improve reliability and avoid costly surprises.
Whether your lift is approaching 15 years or already showing signs of age-related reliability issues, Ideal Lifts can provide condition assessments, modernisation advice and long-term budgeting guidance to help you plan with confidence.
If you’re planning ahead for an ageing lift or would like to learn more, contact our expert team. We’re always happy to help.